Compact Fuel Gas Station
LPQZ Compact Fuel Gas Station combines fuel storage, pumping, metering and dispensing functions in one compact unit. It supports gasoline, diesel and kerosene, with single- or double-layer tank configurations and a flow rate of 5–50 L/min.
Product Overview
LPQZ Compact Fuel Gas Station combines fuel storage, pumping, metering and dispensing functions in one compact unit. It supports gasoline, diesel and kerosene, with single- or double-layer tank configurations and a flow rate of 5–50 L/min.
Compact Fuel Station Design
Integrated Fueling Unit
The station combines the fuel tank, pump, flow meter, dispensing nozzle and control/display components into one compact fueling system.
Compact Equipment Layout
The integrated configuration reduces the space required for separate fuel storage, pumping and dispensing equipment, making the unit suitable for sites where a conventional station layout is impractical.
Main Components
Fuel Storage Tank
The station uses a steel fuel storage tank in single-layer or double-layer construction. Tank capacity and other tank dimensions should be selected according to the required fuel storage volume and project layout.
Fuel Pump
The fuel pump transfers fuel from the storage tank into the dispensing line. The pump configuration is matched to the specified fuel type and station flow requirements.
Flow Meter
The flow meter measures the volume of fuel delivered during dispensing. The listed metering accuracy is 0.25%.
Hose & Dispensing Nozzle
The hose and dispensing nozzle provide the fuel connection between the metering system and the vehicle or receiving equipment. Nozzle quantity is confirmed according to the required fueling configuration.
Dispensing & Display System
The dispensing system controls the fueling operation and displays dispensing information through the LCD display and 775 system.
Fueling Flow Path
Fuel Storage Tank → Fuel Pump → Flow Meter → Hose & Nozzle → Dispensing & Display System
Technical Specifications
|
Item |
Specification |
|
Product Type |
Compact Fuel Gas Station |
|
Model |
LPQZ |
|
Fuel Type |
Gasoline / Diesel / Kerosene |
|
Tank Structure |
Single-layer / Double-layer |
|
Flow Rate |
5–50 L/min |
|
Metering Accuracy |
±0.25% |
|
Flow Meter |
Tatsuno type |
|
Fuel Pump |
Tatsuno type |
|
Power Supply |
AC 220V / AC 380V |
|
Display |
LCD, 775 system |
|
Certification |
CE |
Tank Structure
Single-Layer Tank
A single-layer tank provides the basic fuel storage structure for applications where this tank configuration meets the project requirements.
Double-Layer Tank
A double-layer tank adds a secondary tank layer around the primary fuel storage tank. It can be selected where additional containment is required by the project specification.
Selection Consideration
The appropriate tank structure should be determined by the project requirements, site conditions and applicable local requirements. Single-layer and double-layer configurations should not be treated as interchangeable options for every installation.
Applications
Private Fleet Fueling
The station can be used for refueling company-owned vehicles at fleet yards and other private fueling locations.
Industrial & Construction Sites
It is suitable for projects that need gasoline, diesel or kerosene dispensing and have limited space for fueling equipment.
Remote Fuel Supply Points
The compact unit can serve as a fuel supply point at remote sites where conventional fueling facilities are not available.
Quality Control
Tank Fabrication Inspection
The fuel tank is inspected for welding quality, fabrication condition and the specified single-layer or double-layer construction.
Tank Configuration Check
The tank capacity and specified tank configuration are checked against the confirmed order requirements.
Fueling System Test
The pump, flow meter, hose and dispensing nozzle are checked as an integrated fuel delivery system to verify fuel transfer and dispensing operation.
Metering Check
The flow meter is checked against the specified 0.25% metering accuracy.
Final Configuration Verification
The completed station is checked against the confirmed fuel type, tank structure, tank capacity, nozzle configuration, power supply and display system.

Configuration

Case

Customers And Exhibitions

Delivery And Package

Certificate

FAQ
Q: What information should be confirmed before ordering?
A: Confirm the fuel type, tank structure, tank capacity, nozzle quantity and power supply before production. These parameters determine the station configuration.
Q: How long does it take to put the station into operation after delivery?
A: The station can be put into use within 3–5 days after pipeline connection and safety inspection are completed.
Q: How is the tank capacity selected for an LPQZ compact fuel gas station?
A: Tank capacity should be selected according to required fuel storage volume, site layout and operating demand. The required capacity should be confirmed before production.
Q: What warranty is provided for the station?
A: A one-year warranty is provided for the compact fuel gas station.
Q: Is the equipment supplied as a complete station or as separate components?
A: The fuel storage, metering, pumping and dispensing equipment are integrated into the station configuration and supplied as a complete unit.
Q: Can the station be used for both gasoline and diesel applications?
A: The LPQZ model supports gasoline, diesel and kerosene applications. The required fuel application should be confirmed when ordering.
Hot Tags: compact fuel gas station, China compact fuel gas station manufacturers, suppliers, factory, Compact Fuel Gas Station, Container Filling Station, container fuel station, Diesel Fuel Pump Station, Fuel Dispensing Station, Skid mounted Fuel Station
Send Inquiry